POTENTIAL TOXICITY OF SEAWATER ALONG ADRIATIC COAST, CROATIA
Maja Fafandel *, Nevenka Bihari, Milena Micic, Renato Batel
Center for Marine Research, Rudjer Boškovic Institute, G. Paliaga 5, HR-52210 Rovinj, Croatia - * maja@cim.irb.hr
Abstract
The potential toxicity of organic extracts from 12 seawater samples per 24 sampling sites, collected during 1999-2001 period along
Adriatic coast, Croatia, was analyzed by Microtox
7
bioassay. Discrimination between sampling sites according to their potential seawater
toxicity was achieved by cluster analysis. The water quality of selected sites could be described as excellent at one sampling site (mean
EC50 > 625), good at 15 sampling sites (375 < mean EC50 < 625) and fair at 8 sampling sites (EC50 < 375). 
Keywords: Adriatic Sea, Microtox
7
, seawater toxicity
Rapp. Comm. int. Mer Médit., 37,2004
193
Introduction
The Adriatic sea, as a semienclosed part of the Mediterranean Sea
is of special interest for an evaluation of environmental pollution. We
hypothesized that by assesing the potential toxicity of seawater
collected at 24 sites along Adriatic coast (Croatia) four times per year
for 3 years, one could get a better insight into the general seawater
quality at each sampling site. Physical-chemical properties of the Split
region waters showed to be the most polluted along the Croatian
Adriatic coast (1). The levels of PCBs from the Adriatic Sea sediment
samples (1976-1992) were significantly lower compared to samples
from areas of the south coast of France, west coast of Italy and east
coast of Greece (2).The aim of the study was to determine the
potential toxicity load of the main “hot spots”along the Adriatic
coast, Croatia. Cluster analysing was introduced for discrimination
between groups according to their toxicity load. 
Materials and methods
The investigated sites were along Adriatic coast, Croatia, in the
vicinity of urban and industrial areas (Rijeka, Zadar, Šibenik, Split,
Dubrovnik) under the influence of human activities. For potential
toxicity testing, seawater was collected at: mariculture (site 1),
protected (sites 2, 3), urban (sites8, 9, 10, 11, 13, 14, 15, 18),
industrial (sites 16,17), harbour ( sites 4, 5, 6, 7, 12, 19, 24) and
brackish(sites 20, 21, 22, 23). Surface seawater was collected at 0.5
m depth at each sampling site in March, June, August and October
from 1999 - 2001. Non-polar compounds were extracted (3),
dissolved in DMSO (300 µl) and stored at -20 
o
C. Decline in
luminescence of marine bacterium Vibrio fischeriNRRLB-11177
(DIN EN ISO 11348-3) was measured in the Microtox
7
bioassay.
Maximal tested amount corresponded to 1250 ml of seawater.The
results were expressed as ml of seawater causing a 50% reduction of
bioluminescence after 15 minutes (EC50). To detect groupings in
EC50 data (minimum, maximum, mean and median) a cluster
analysis (complete linkeage method, Euclidean distances) was
applied. To verify the groupings K-means clustering was performed.
Results and discussion
Microtox
7
bioassay provides a response to a single toxicant or a
combined effect of many toxicants when their concentration exeeds
treshold limit. It was succesfully applied for detection of sediment and
seawater toxicity (4, 5, 6) as well as for accidental toxic events (7).We
observed broad range and high variation of EC50 values at each
investigated site. Due to the high standard deviations at each sampling
site, Kruskal-Wallis test showed no statistical differences between
sampling sites. Therefore, the cluster analysis as a multivariate
procedure for detecting natural grouping of data was performed.
Hierarchical tree sorted samling sites in clusters in such a way that
sites with similar toxicity data appear in the same cluster while sites
with dissimilar toxicity data in different clusters (Fig. 1).Three-group
K-means method produced partitioned clusters identical to 3 clusters
(each case p<0,05) separated at 60% similarity in the joining tree.
First cluster comprise sampling site 21 with mean EC > 625 ml
(Fig.2), second cluster 15 sampling sites (2, 3, 6, 7, 8, 9, 10, 12, 13,
16, 18, 19, 22, 23, 24) with 375 < mean EC50 < 625 and third cluster
comprised 8 sampling sites (1, 4, 5, 11, 14, 15, 17, 20) with mean
EC50 <375. Our investigation based on determination of potential
toxicity of seawater organic extracts mirrored the present status of
seawater quality and background levels of potential toxicity at 24
selected sites along Adriatic coast, Croatia. 
Fig. 1. Cluster analysis tree diagram of toxicity data (EC50) obtained
from 12 samplings at 24 investigated sites along Adriatic coast, Croatia.
Fig. 2. Classification of 24 sampling sites along Adriatic coast, Croatia
according to seawater toxicity: group I - mean EC50 > 625, group II - 375
< EC50 < 625, group III - EC50 < 375. 
References
1-Vukadin I., Stojanovski L.1998. Proceedings: Present water quality of
Kastela Bay (Adriatic Sea) and some proposal for its protection and
improvement. Kastela kolijevka Hrvatske, Matica Hrvatska, Kastela.
ISBN 963-6370-10-7.
2-Picer M., Picer N. 1997. DDT and PCBs levels and long-term trends in
sediments collected from the eastern coastal and open waters of the
Adriatic Sea. Organohal. Comp.,32:198-203.
3-Hamer B., Bihari N., Reifferscheid G., Zahn R.K., Muller W.E.G.,
Batel R. 2000. Evaluation of the SOS/umu-test post-treatment assay for
the detection of genotoxic activities of pure compounds and complex
environmental mixtures. Mutat. Res. Gem. Tox. En., 406(2):161- 171.
4-Quinou F., Judas A., Lesquerande E. 1997.Assesment of potential
toxicityin estuary water and sediments in the Bay of Brest using two types
of bioassay. Ann. Inst. Oceanogr.,73:35-48.
5-Passarini F., Rampazzo G., Ghirardini A.V., Sperni L., Salizzato M.,
Pavoni B. 2000. Extraction, identification and quantification of heavy
metals in Venice Lagoon sediments using toxicity tests with
microorganisms. Ann. Chim.,90: 91-101.
6-Boluda R., Quinanilla J.F., Bonilla J.A., Saez E., Gamon M. 2002.
Application of the Microtox test and pollution indeces to the study of
toxicity in the Albufera Natural Park, Valencia, Spain. Chemosphere, 46:
355-369.
7-Bihari N., Najdek M., Floris R., Batel R., Zahn R.K. Sediment toxicity
assesment using bacterial bioluminescence: effect of an unusual
phytoplankton bloom. Mar. Ecol. Prog. Ser.,37: 307-310.